Customization: | Available |
---|---|
Type: | Submersible |
Contact: | Contactless |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Process temperature | -50 ... 250 °C [°C - °F] |
Process pressure | -14.5 ... 928 psi [Bar - kPa - psi] |
Version | Standard Hygienic applications with gas-tight leadthrough with temperature adapter |
Materials, wetted parts | PFA 316L Alloy C22 (2.4602) Alloy 400 (2.4360) ECTFE Enamel |
Flange connection | ≥ DN25, ≥ 1" |
Threaded connection | ≥ G¾, ≥ ¾ NPT |
Hygenic fittings | Clamp ≥ 1" - DIN32676, ISO2852 Slotted nut ≥ 1½", ≥ DN40 - DIN 11851 Varivent ≥ DN25 hygienic fitting F40 with compression nut SMS 1145 DN51 SMS DN38 Hygienic fittings ≥ DN25 - DIN11864-1-A Hygienic flange connection DIN11864-2-A; DN60(ISO)ø60,3 SMS socket piece DN38 PN6 |
Seal material | no media contact |
Housing material | Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished) |
Protection rating | IP66/IP67 IP66/IP68 (1 bar) IP65 |
Output | Relay (DPDT) Contactless electronic switch Transistor (NPN/PNP) Two-wire NAMUR |
Ambient temperature | -40... 80 °C |